Photon TG-51 Calculator | Automated Linac Output Calibration & QA Web App
Photon TG-51 Calculator – Automated Linac Output Calibration & QA
Simplify photon beam output calibration calculations with a dedicated, locally hosted TG-51 web application.
Designed for medical physicists, this application streamlines reference dosimetry calculations for both flattened and flattening-filter-free (FFF) photon beams, following the AAPM TG-51 protocol and the 2014 photon addendum.
Whether you're performing annual linac calibration, reviewing measurement data, or teaching TG-51 dosimetry, this tool provides a convenient interface for calculations, documentation, and historical measurement review.
✨ Key Features
🔬 Automated TG-51 Calculations
- Calculate absorbed dose to water using the TG-51 formalism.
- Apply temperature-pressure (Ptp), polarity (Ppol), ion recombination (Pion), and electrometer (Pelec) corrections.
- Calculate beam-quality conversion factors (kQ).
- Support flattened and FFF photon beams.
⚡ Flexible Reference Dosimetry Setup
- Support SAD-based photon reference measurements.
- Select PDD- or TMR-based beam-quality workflows.
- Automatically use the appropriate calculation tables based on the selected measurement method.
- Enter ion chamber calibration and measurement parameters through an intuitive interface.
📊 Output Verification and QA
- Calculate photon reference dose and output.
- Compare measured output against expected values.
- Display percentage differences for efficient QA review.
- Review calculation details and intermediate correction factors.
💾 Local Database and Measurement Records
- Save calibration measurements and calculation results.
- Maintain historical records for reference and comparison.
- Store data locally without requiring a cloud-based service.
- Support organized annual QA documentation.
💻 Local Web Application
- Run the application on your own computer.
- Access the interface through a web browser.
- No external server or cloud account required.
- Source code can be reviewed and customized for institutional workflows.
👩⚕️ Who Is This For?
- Therapeutic medical physicists
- Medical physics residents and students
- Radiation oncology departments
- Clinical educators
- Physicists developing automated QA workflows
📦 What's Included?
- Photon TG-51 web application source code
- Local application setup instructions
- Database setup guidance
- Example measurement data for demonstration and testing
📚 Technical Reference
The application implements photon reference dosimetry calculations based on:
- AAPM TG-51 (1999): Clinical Reference Dosimetry of High-Energy Photon and Electron Beams
- AAPM TG-51 Photon Addendum (2014)
⚠️ Important Disclaimer
This software is provided as an educational, research, and independent calculation-support tool. It is not an FDA-cleared medical device and has not been independently validated for clinical use at your institution.
Users are responsible for verifying all calculations, beam-quality corrections, measurement conventions, and results against applicable protocols and independently validated clinical procedures before relying on them for clinical decisions.
Make TG-51 calculations more efficient, transparent, and reproducible.