Your Cart
Loading

Compressor Service Valves — Adding Refrigerant the Quarter-Turn Way

On Sale
$12.00
$12.00
Added to cart

EBOOK + AUDIOBOOK TOGETHER — one bundle, one price.

📚 MORE BOOKS: tap the Reefer Works name at the very top of this page to open the whole store — all our reefer training ebooks are there, each in its own collection.

🎧 AUDIOBOOK INCLUDED: listen to the whole lesson walked through in plain words while you follow the pages.

From the Reefer Works lesson library — a field lesson now in book form.

BEFORE YOU START — PLEASE READ: This book is SHORT, and it says so plain: the whole book is one complete field lesson — the compressor service valve, its four positions, and the quarter turn that adds refrigerant. Nothing is padded, nothing is added, and nothing is left out. It works the suction service valve on top of the compressor — the low side — and the same kind of valve sits on Carrier units and on Thermo King units.

WHAT'S INSIDE

  • THE FOUR POSITIONS (ebook p. 3) — full out is back seated, the normal running position; a quarter turn in is "cracked" open to the service port; in half way is mid seated; full in is front seated. With the manual page from the lesson — the red in each drawing is the refrigerant path — and the gauge connections the same page shows: compressor oil pressure and receiver tank pressure.
  • THE VALVE UP CLOSE (ebook p. 4) — where the valve lives on top of the compressor; the black safety cap and what it protects (it keeps the refrigerant in if the valve starts leaking); the gauge tap where your gauges connect; and the stem your wrench turns. Photo from the lesson: the real valve, finger on the cap.
  • THE QUARTER TURN IN (ebook p. 5) — adding refrigerant step by step: gauges on the tap, safety cap off, turn the stem CLOCKWISE one quarter turn from full out, watch the inner part open inside the valve, and add the refrigerant your unit needs.
  • CLOSE IT BACK, AND THE WARNING (ebook p. 6) — closing the valve after the charge; the part inside that stays open to the system; why you never close it all the way off with the compressor running; and the factory warning in full: service valve stems and service ports must be properly capped and torqued with seals or O-rings installed — stems and ports not properly capped WILL LEAK refrigerant.

How it works: the audio walks the book section by section, in order — it isn't locked page-by-page, so you flip the pages at your own pace, and you can pause and rewind anytime. Technicians like to follow along — that's why this audiobook exists.

More Reefer Works ebooks are on the way — reefer training books and more trailer, truck and tractor service books.

Checkout note: your statement will show a PayPal charge under the name Ross (Reefer Works).