Your Cart
Loading

Carrier Phoenix Xtra, Advantage & Multi-Temp Service Manual

On Sale
$22.99
$22.99
Added to cart

Carrier Phoenix Xtra, Advantage & Multi-Temp Service Manual — the complete Carrier factory operation and service manual 62-02426 as an ebook.


📚 MORE BOOKS: tap the Reefer Works name at the very top of this page to open the whole store — all our reefer training ebooks are there, each in its own collection.

🎧 The bundle includes the audiobook — see the bundle and the free sample

The ebook alone does not include audio. The Ebook + Audiobook Bundle includes the ebook plus the full audiobook.

Format: PDF ebook, 85 pages.

Carrier Transicold operation and service manual 62-02426 — Operation and Service for the Phoenix Xtra, Phoenix Advantage and Phoenix Multi-Temp trailer refrigeration units: the NDA-79 and NDA-89 nosemount diesels, running R-502.

BEFORE YOU START — PLEASE READ: This is the complete factory manual as it came to us — all 82 of Carrier's own pages, unaltered and in order: description, operation, troubleshooting, service, the wiring schematic, and the full multi-temp section with its own schematics. Nothing is missing and nothing is reordered. One honest note: this manual has no index — the full table of contents in the front pages is the way in.

WHAT'S INSIDE

  • THE MANUAL'S OWN FRONT PAGES (ebook p. 4) — Carrier's title pages, the full table of contents, and the lists of illustrations and tables for the whole manual.
  • 1. DESCRIPTION AND INTRODUCTION (ebook p. 11) — the Phoenix trailer refrigeration units, models NDA-79 and NDA-89: the unit, its engine, compressor and controls, end to end.
  • UNIT DATA (ebook p. 17) — engine data, refrigeration system data, the safety devices table, engine screw threads, the engine air system, and the lube oil and fuel flow diagrams.
  • COMPRESSOR UNLOADERS AND THE CHARGING SYSTEM (ebook p. 19) — how the unloaders stage capacity, and the battery charging alternator system with its integral voltage regulator.
  • THE MICROPROCESSOR CONTROLLER (ebook p. 22) — controls and display, status and caution indicators, the digital display, defrost mode failure, controller interface connections, and optional MicroLink remote monitoring.
  • AUTO START, SWITCHES AND CONTROLS (ebook p. 28) — auto start operation, the control panel and its components, where the engine safety devices sit, and the optional condenser shutters and covers.
  • REFRIGERANT CIRCUITS (ebook p. 33) — the circuit during cooling, and during heating and defrosting.
  • 2. OPERATION (ebook p. 35) — the pre-trip inspection, starting and stopping on engine drive and on auto start, and control circuit operation for preheat, cooling, heating and defrost.
  • 3. TROUBLESHOOTING (ebook p. 41) — engine will not start, starts then stops, starter and starting-circuit faults, the alternator, and the full refrigeration fault tables: cooling, heating, defrost, pressures, noise and air flow.
  • 4. SERVICE: MAINTENANCE AND THE ENGINE (ebook p. 47) — the maintenance schedule (daily, 400, 1000 and 3000 to 6000 hour), priming the fuel system, engine service, the alternator checks, and V-belt service and tension.
  • 4B. SERVICE: THE REFRIGERANT CIRCUIT (ebook p. 56) — removing the charge and pumping down, leak checking, evacuation and dehydration, adding refrigerant (full and partial charge), purging noncondensibles, and replacing the compressor.
  • 4C. SERVICE: COMPONENTS (ebook p. 62) — compressor oil level, the unloader valve, check valve, filter-drier, high pressure cutout switch, receiver sight glass, the solenoid valves and the SV-1 checkout, and the defrost checks.
  • 4D. SERVICE: VALVE, CONTROLLER AND SENSORS (ebook p. 69) — the thermostatic expansion valve, microprocessor service, controller air sensor and suction pressure transducer checkouts, condenser shutter service, evaporator coil cleanliness, and the unidrive torque requirements.
  • 5. ELECTRICAL SCHEMATIC WIRING DIAGRAM (ebook p. 74) — drawing 62-03833 with its legend, the full schematic for the single-temp Phoenix units.
  • 6. MULTI-TEMP OPERATION AND SERVICE (ebook p. 77) — the multi-temp system: electrical data, safety devices, the refrigerant circuit, remote compartment operation, servicing the remote evaporator, the liquid solenoid valve, the evaporator pressure regulating valve, the generator belt, and the multi-temp schematics.

How it works: the audio walks the book section by section, in order — it isn't locked page-by-page, so you flip the pages at your own pace, and you can pause and rewind anytime. Technicians like to follow along — that's why this audiobook exists.

More Reefer Works ebooks are on the way — reefer training books and more trailer, truck and tractor service books.

Checkout note: your statement will show a PayPal charge under the name Ross (Reefer Works).

Not sure yet? Get the FREE SAMPLE first — hear the intro and first section free: https://payhip.com/b/BD25O

You will get a PDF (3MB) file