Carrier Genesis TM900 & TM1000 Multi-Temp Service Manual
Carrier Genesis TM900 & TM1000 Multi-Temp Service Manual — the complete Carrier factory service manual 62-10022-01 as an ebook.
📚 MORE BOOKS: tap the Reefer Works name at the very top of this page to open the whole store — all our reefer training ebooks are there, each in its own collection.
🎧 The bundle includes the audiobook — see the bundle and the free sample
The ebook alone does not include audio. The Ebook + Audiobook Bundle includes the ebook plus the full audiobook.
Format: PDF ebook, 100 pages.
Carrier Transicold service manual 62-10022-01 — Operation and Service for the Genesis TM900 and Genesis TM1000 Multi-Temp trailer refrigeration units, for units prior to serial number HAY90594029.
BEFORE YOU START — PLEASE READ: This is the complete factory manual as it came to us — all 97 of Carrier's own pages, unaltered and in order: description, operation, troubleshooting, service, the wiring schematics, the standby-motor section, and the index. Nothing is missing and nothing is reordered.
WHAT'S INSIDE
- THE MANUAL'S OWN FRONT PAGES (ebook p. 4) — Carrier's title pages, the full table of contents, and the lists of illustrations and tables for the whole manual.
- 1. DESCRIPTION AND INTRODUCTION (ebook p. 11) — the Genesis Multi-Temp system: two or three compartments, any compartment at any temperature; models NDA93 and NDA94; the nosemount unit, its evaporators and its 5-kilowatt generator; the model chart, Table 1-1 (R-22 or R-404A, 28-lb charge, 05G compressor, CT4-134 diesel at 1700 RPM).
- UNIT DATA (ebook p. 18) — engine data for the CT4-134 diesels, 05G compressor data, refrigeration system data, electrical data, and the safety devices table: what protects the unit and at what settings.
- COMPRESSOR UNLOADERS (ebook p. 21) — unloading in temperature mode, suction pressure operation, unloading during 4-kW heating (R-404A only), and the hot gas bypass unloader, loaded and unloaded.
- THE MICROPROCESSOR CONTROLLER (ebook p. 24) — the keypad, setting the setpoint, the digital display, and the functional parameters — the function codes the controller works by.
- UNIT DATA, ALARMS, PRE-TRIP AND AUTO START/STOP (ebook p. 27) — the unit data codes, the alarm display list, pre-trip, heat/cool mode, the defrost cycle, the auto start/stop sequence, DataTrak remote monitoring, and the switches and controls.
- REFRIGERANT CIRCUITS (ebook p. 37) — the R-404A and R-22 circuit diagrams for cooling, and for heating and defrosting, Figures 1-18 through 1-21.
- 2. OPERATION (ebook p. 43) — the pre-trip inspection, starting and stopping instructions, manual start and the glow-time table, remote compartment operation with pre-set setpoints, and control circuit operation for cooling, heating and defrost.
- 3. TROUBLESHOOTING: ENGINE AND ALTERNATOR (ebook p. 51) — engine will not start, engine starts then stops, starter motor malfunction, faults in the engine starting circuit, and the automotive-type alternator.
- 3B. TROUBLESHOOTING: REFRIGERATION AND GENERATOR (ebook p. 53) — unit will not cool, insufficient cooling, long or continuous cooling, heating and defrost faults, abnormal pressures in cooling and heating, abnormal noise, control system and air flow faults, expansion valve and solenoid valve faults, and the 5 kW generator checks.
- 4. SERVICE: MAINTENANCE AND THE ENGINE (ebook p. 57) — the maintenance schedule, priming the fuel system, engine service (air cleaner, breather, fuel pumps, glow plugs), and V-belt service and tension for every belt on the unit.
- 4B. SERVICE: THE REFRIGERANT CIRCUIT (ebook p. 62) — pumping the unit down and removing the charge, refrigerant leak checking, evacuation and dehydration, and adding refrigerant — full charge, and partial charge (R-22 only).
- 4C. SERVICE: COMPRESSOR AND REFRIGERATION PARTS (ebook p. 64) — replacing the compressor, checking compressor oil level, the unloader valve, the check valve, filter-drier, high pressure cutout switch, receiver sight glass, solenoid valves and their checkout, defrost checks and the defrost air switch, fan shafts and bearings, coil cleaning, the thermostatic expansion valve, and the evaporator fan motor.
- 4D. SERVICE: CONTROLLER, GENERATOR AND CLUTCH (ebook p. 75) — microprocessor service and the full configuration procedure, controller sensors, unidrive torque requirements, the liquid solenoid valve, generator service and generator flashing, and the gearbox clutch.
- 5. ELECTRICAL SCHEMATIC WIRING DIAGRAMS (ebook p. 84) — the five NDA schematics, drawings 62-03997 through 62-04014, matched to the unit by serial number, including the R-404A diagram.
- 6. MODEL NDM UNITS WITH STANDBY MOTOR (ebook p. 91) — the standby-motor model: its model chart and electrical data, the speed control solenoid and linkage, standby motor V-belts, servicing the standby clutch, and the NDM schematics.
- INDEX (ebook p. 99) — the manual's own alphabetical index, so any part, procedure or setting in the book is one look-up away.
How it works: the audio walks the book section by section, in order — it isn't locked page-by-page, so you flip the pages at your own pace, and you can pause and rewind anytime. Technicians like to follow along — that's why this audiobook exists.
More Reefer Works ebooks are on the way — reefer training books and more trailer, truck and tractor service books.
Checkout note: your statement will show a PayPal charge under the name Ross (Reefer Works).
Not sure yet? Get the FREE SAMPLE first — hear the intro and first section free: https://payhip.com/b/S8JOr