Full Diagnostic & Testing Service Guide, complete with electrical schematics, covering the John Deere 1775NT 24-Row Planter equipped with ExactEmerge Row Units — everything needed to keep, troubleshoot, and repair this machine the way a professional technician would.


The Diagnosis & Tests workshop manual for the John Deere 1775NT 24-Row Planter with ExactEmerge Row Units contains:


* Numbered table of contents easy to use so that you can find the information you need fast.


* Detailed sub-steps expand on repair procedure information


* Numbered instructions guide you through every repair procedure step by step.


* Troubleshooting and electrical service procedures are combined with detailed wiring diagrams for ease of use.


* Notes, cautions and warnings throughout each chapter pinpoint critical information.


* Bold figure number help you quickly match illustrations with instructions.


* Detailed illustrations, drawings and photos guide you through every procedure.


* Enlarged inset helps you identify and examine parts in detail.


tm139519 - 1775NT 24-Row Planters with ExactEmerge Row Units Diagnosis and Tests Technical Manual.pdf


tm139519 - 1775NT 24-Row Planters with ExactEmerge Row Units Diagnosis and Tests Technical Manual.epub


PRODUCT DETAILS:


Total Pages: 2,114 pages


File Format: PDF/EPUB/MOBI/AZW (PC/Mac/Android/Kindle/iPhone/iPad; bookmarked, ToC, Searchable, Printable)


Language: English


MAIN SECTIONS


Foreword


General Information


Acronym Table


How to Use This Manual


Safety


Lubricants


Recommended Tools for Diagnostics


Basic Diagnostics


Diagnostic Information for Electrical Components


Diagnostic Information for Hydraulic Components


Maintaining Hydraulic Systems and Components


Standard Torque Chart Procedures


Diagnostic Trouble Codes


Accessing Diagnostic Trouble Codes


Planter Main 1 (PM1) Codes


Planter Main 2 (PM2) Codes


Observable Symptoms and System Diagnostics


Observable Symptoms


Electrical


General Information


Theory of Operation


Schematics


Diagnostics


Electronic Control Units


Accessing Diagnostic Addresses


Diagnostic Addresses by Control Unit


Diagnostics


Electrical Component Information


Electrical Assemblies


Sensors


Lights


Fuses


Charging


Relays


Motors


Switches


Diodes


Interconnects


Electronically Actuated Mechanical Devices


Hydraulics


Theory of Operation


Schematics


Diagnostics


Hydraulic Components


Accumulator


Cylinder, Actuator, or Piston


Check Valve


Filter


Valve Block, Assembly, or Gearcase


Cooler


Motor


Orifice


Reservoir Tank


Valve


Diagnostic Receptacle or Coupler


Solenoid Valve


Pneumatics


Theory of Operation


Schematics


Diagnostics


Pneumatic Components


Accumulators


Sensors


Check Valves


Filters


Assembly Groups


Pumps


Reservoirs


Switches


Valves


Couplers or Diagnostic Receptacles


Solenoid Valves


tm139519 - 1775NT 24-Row Planters with ExactEmerge Row Units Diagnosis and Tests


Table of Contents


Foreword


Section 210: General Information


Group 5A: How to Use This Manual


Information is Available in Sections, Groups and Subgroups


Group 5B: Safety


Work In Ventilated Area


Recognize Safety Information


Avoid Backover Accidents


Prevent Machine Runaway


Avoid Contact with Agricultural Chemicals


Clean Vehicle of Hazardous Pesticides


Use a Safety Chain


Work in Clean Area


Decommissioning — Proper Recycling and Disposal of Fluids and Components


Prepare for Emergencies


In Case of Fire


Use Safety Lights and Devices


Avoid High-Pressure Fluids


Use Proper Lifting Equipment


Illuminate Work Area Safely


Live With Safety


Support Machine Properly


Freeing a Mired Machine


Protect Against Noise


Remove Paint Before Welding or Heating


Park Machine Safely


Prevent Acid Burns


Follow Safety Instructions


Use Proper Tools


Keep Riders Off Machine


Service Tires Safely


Stay Clear of Rotating Drivelines


Construct Dealer-Made Tools Safely


Practice Safe Maintenance


Understand Signal Words


Replace Safety Signs


Prevent Battery Explosions


Protect Against High Pressure Spray


Avoid Heating Near Pressurized Fluid Lines


Tow Loads Safely


Transport Towed Equipment at Safe Speeds


Observe Maximum Transport Speed


Wear Protective Clothing


Precautions for Welding


Handle Agricultural Chemicals Safely


Service and Operate Chemical Sprayers Safely


Relieve Hydraulic Pressure Safely


Use Steps and Handholds Correctly


Group 5C: Lubricants


Grease


Gear Oil


Alternative and Synthetic Lubricants


Lubricant Storage


Group 5D: Recommended Tools for Diagnostics


Recommended Tools


Group 5E: Diagnostic Philosophy


Basic Diagnostic Philosophy


Systematic Diagnostic Approach Overview


Troubleshooting Unresolved Problems


Group 5F: Diagnostic Information for Electrical Components


Electrical Designators


Visually Inspect Electrical System


Group 5G: Diagnostic Information for Hydraulic Components


Hydraulic Designators


Troubleshooting Tips


Visually Inspect Hydraulic System


Group 5H: Maintaining Hydraulic Systems and Components


Hydraulic Components


Oil Storage and Filling


Oil Filtration


Group 5I: Standard Torque Chart Procedures


Unified Inch Bolt and Screw Torque Values


Metric Bolt and Screw Torque Values


Group 5J: Acronym Table


Acronym Table


Section 211: Diagnostic Trouble Codes


Group 10A: Accessing Diagnostic Trouble Codes


Accessing Diagnostic Trouble Codes


Group 10B: Closing Wheel Controller (CWC) Codes


CWC 001351.14 - Air Supply System


CWC 001387.00 - System control disabled


CWC 001387.01 - System control disabled


CWC 001387.03 - Closing Wheel Control System


CWC 001387.04 - Closing Wheel Control System


CWC 001387.10 - System control disabled


CWC 001387.13 - Closing Wheel Control System


CWC 001387.14 - Closing Wheel Control System


CWC 001387.16 - Pressure too high on Closing Wheel Group 1


CWC 001387.17 - Moderate leak detected on Closing Wheel Group 1


CWC 001388.00 - System control disabled


CWC 001388.01 - System control disabled


CWC 001388.03 - Closing Wheel Control System


CWC 001388.04 - Closing Wheel Control System


CWC 001388.10 - System control disabled


CWC 001388.13 - Closing Wheel Control System


CWC 001388.14 - Closing Wheel Control System


CWC 001388.16 - Pressure too high on Closing Wheel Group 2


CWC 001388.17 - Moderate leak detected on Closing Wheel Group 2


CWC 003509.03 - Sensor Voltage is above Normal


CWC 003509.04 - Sensor Voltage is below Normal


CWC 517151.01 - Closing Wheel Control System


CWC 517151.03 - Closing Wheel Control System


CWC 517151.04 - Closing Wheel Control System


CWC 517151.05 - Closing Wheel Control System


CWC 517151.06 - Closing Wheel Control System


CWC 517151.12 - Closing Wheel Control System


CWC 517152.03 - Closing Wheel Control System


CWC 517152.04 - Closing Wheel Control System


CWC 517152.12 - Closing Wheel Control System


CWC 517153.01 - Closing Wheel Control System


CWC 517153.03 - Closing Wheel Control System


CWC 517153.04 - Closing Wheel Control System


CWC 517153.05 - Closing Wheel Control System


CWC 517153.06 - Closing Wheel Control System


CWC 517153.12 - Closing Wheel Control System


CWC 517154.03 - Closing Wheel Control System


CWC 517154.04 - Closing Wheel Control System


CWC 517154.12 - Closing Wheel Control System


CWC 517154.31 - Closing Wheel Control System


CWC 520463.03 - Closing Wheel Control ECU Power


CWC 520463.04 - Closing Wheel Control ECU Power


CWC 523218.03 - Valve Power 2 Voltage Above Normal


CWC 523218.04 - Closing Wheel Control Valve Power 2


CWC 523218.05 - Closing Wheel Control Valve Power 2


CWC 523438.02 - EEPROM Checksum Error


CWC 523438.14 - EEPROM Out of Bounds Error


Group 10C: Electric Power Generation (EPG) Codes


EPG 000158.00 - ECU 12 Volt Supply Out of Range High


EPG 000158.01 - ECU 12 Volt Supply Out of Range Low


EPG 000167.00 - 56 Volt Bus Error


EPG 000167.01 - Planter 56 V Bus Too Low for Operation


EPG 000167.03 - 56 Volt Bus Voltage Sense Line Issue


EPG 000167.17 - Planter 56 V Bus Too Low for Good Performance


EPG 000186.01 - PTO Not Engaged or Not Spinning While Engaging Alternator


EPG 000444.01 - Depleted High Voltage Battery Bank Detected


EPG 000444.03 - Battery Bank Voltage Sense Line Issue


EPG 000444.04 - Excessive Battery Bank Discharge Detected


EPG 000444.17 - Excessive Usage of Battery Bank During Planting Detected


EPG 000444.18 - Low High Voltage Battery Bank Detected


EPG 000589.00 - Planter Power Generation Alternator Over Speed Detected


EPG 001762.00 - Hydraulic Pressure Sensor Signal Out of Range High


EPG 001762.01 - Hydraulic Pressure Sensor Signal Out of Range Low


EPG 001762.05 - Missing Hydraulic Pressure Sensor Signal


EPG 001762.07 - Hydraulic Pressure Not Detected


EPG 002197.08 - Seed Monitor Online but Not Responding to CAN Messages


EPG 002197.09 - Seed Monitor Controller is Offline


EPG 002197.19 - External User Command Synchronization Error Detected


EPG 002634.05 - Battery Contactor Failed to Close


EPG 002634.06 - Battery Contactor Failed to Open


EPG 003380.00 - Tractor Voltage Supply is High


EPG 003380.01 - Alternator Excitation Voltage Low


EPG 003380.17 - Alternator Excitation Voltage Low


EPG 516207.03 - 56 Volt Alternator Relay


EPG 516207.05 - 56 Volt Alternator Relay


EPG 516207.06 - 56 Volt Alternator Relay


EPG 516207.16 - 56 Volt Alternator Relay


EPG 516207.17 - 56 Volt Alternator Relay


EPG 516207.18 - 56 Volt Alternator Relay


EPG 517131.00 - PTO Power Generation


EPG 517131.01 - PTO Power Generation


EPG 517131.15 - PTO Power Generation


EPG 517131.16 - PTO Power Generation


EPG 520440.05 - Battery Contactor Open Circuit Fault Detected


EPG 520440.06 - Battery Contactor Short Circuit Fault Detected


EPG 520440.07 - Battery Energy Storage


EPG 521065.00 - 56 V Load Current Sensor Outside of Expected Operation Range


EPG 521065.01 - 56 V Load Current Sensor Zero Value Out of Range


EPG 521065.02 - 56 V Load Current Sensor Signal Erratic


EPG 521065.05 - 56 V Load Current Sensor Signal Missing


EPG 521065.10 - High Voltage Load Current Sensor Installed Backwards


EPG 521983.00 - ELX 12 Volt Supply Out of Range High


EPG 521983.01 - ELX 12 Volt Supply Out of Range Low


EPG 523652.07 - 56 V Load Current Sensor Harness Issue


EPG 524010.03 - Flow Control Valve HSD Short to Battery


EPG 524010.04 - Valve Power Voltage Below Minimum Voltage Required


EPG 524010.06 - Flow Control Valve HSD Short to Ground


EPG 524010.106 - Flow Control Valve LSD Short to Ground


EPG 524010.17 - Flow Control Valve LSD Open Circuit


EPG 524010.18 - Flow Control Valve LSD Short to Battery


EPG 524039.00 - Power Generation Hydraulic Motor Over Speed Detected


EPG 524039.01 - Power Generation Hydraulic Motor Speed Signal Missing


EPG 524039.11 - Hydraulic Motor Failed to Reach Soft Start Exit Conditions


EPG 524039.16 - Power Generation Hydraulic Motor Spinning Uncommanded


EPG 524039.18 - Power Generation Hydraulic Motor Unable to Achieve Target Speed


Group 10D: Inertial Measurement Unit (IMU) Codes


IMU 520870.02 - EEPROM Checksum Error


IMU 521396.12 - Gyroscope Sensor


Group 10E: JDLink (JDL) Codes


JDLink Diagnostic Trouble Codes


Group 10F: Meter Master Controller (MMC) Codes


MMC 000046.03 - Air Supply System


MMC 000046.06 - Air Supply System


MMC 000046.13 - Air Supply System


MMC 000046.14 - Air Supply System


MMC 000084.09 - Wheel Speed Not Detected On CAN Bus


MMC 000444.04 - Battery Potential (Voltage) / Power Input 2 Low Voltage


MMC 000609.02 - The following Row Unit Controllers are not responding to CAN bus commands


MMC 000609.12 - The Following Row Unit Controllers are Offline


MMC 000628.02 - MMC EOL Data Revision Mismatch


MMC 000639.12 - CAN Bus 1 Communication System


MMC 000639.14 - CAN Bus 1 Communication System


MMC 000705.03 - These Rows Have a Downforce Sensor Error


MMC 000705.04 - These Rows Have a Downforce Sensor Error


MMC 000705.13 - Gauge Wheel Downforce Sensor Problem


MMC 000705.14 - Gauge Wheel and Vacuum Sensor Configuration is Reset


MMC 000838.02 - These Row Unit Controllers Have an Addressing Error


MMC 000838.03 - These Row Unit Controllers Have an Addressing Error


MMC 000838.04 - These Row Unit Controllers Have an Addressing Error


MMC 001231.12 - CAN Bus 2 Communication System